24-hour service hotline:13739711047

CN   |   EN

 

Welcome to Hebei Nouan Technology Co., Ltd. official website!

Company address:

No. 89 Huanghe Avenue, Shijiazhuang City, Hebei Province

Company phone:

13739711047

Company email:
hbnakj@163.com

WeChat

Alibaba 

Hebei Nuoan Technology Co., Ltd.

Since the launch of the company's products, its reliable performance, user-friendly design, reasonable price and perfect after-sales service have laid a good foundation for the company to establish a corporate image and conduct business.

Mobile


Hebei Nuoan Science and Technology Co., Ltd. All rights reserved.                                                                                                   冀ICP备15009982号-1      Powerd by:300.cn

PRODUCT CENTER

Page view

American Enerac 500 Portable Flue Gas Analyzer

CO,flammablegasandprofessionalsmokeanalysis.Optionallargerange.Built-inthermalprinter.Operatingsoftware:PalmandwindowsCE.Youcanselectivelypurchaseonlythefeaturestosaveonpurchasingcosts.Thebootsystemis
Affiliate classification
Quantity
-
+
没有此类产品
Inquiry
Sample
Product Details

CO, flammable gas and professional smoke analysis.

Optional large range.

Built-in thermal printer.

Operating software: Palm and windowsCE.

You can selectively purchase only the features to save on purchasing costs.

The boot system is automatically calibrated and free of commissioning.

(4-6h) 4xAA rechargeable battery of low energy consumption

Discounts are available for product upgrade.

 

Technical Parameters:

 

Box size: 248 x 102 x 70 mm, aluminum alloy case. Weight: 1.4 kg

Probe: Nickel alloy probe of 230 mm long, 9.6 mm outer diameter. The probe and instrument are connected by a 3.2M long VITON tube to a condenser with a fiber filter. The highest continuous measurement temperature is: 1090 ° C

Battery (DC): 6 volt replaceable NiMH (or NiCd) rechargeable battery, or 4 alkaline batteries. Approximately 6-8 hours of running time.

AC: 120V, 60 Hz standard battery charger, or an optional 22V, 50 Hz battery charger. (Only for rechargeable batteries)

Four-screen data display, 16-pixel high-definition LCD display (with backlight)

Built-in thermal printer (28 bytes per line, 51mm wide)

100 separate buffers can store 100 sets of measured data, which will not be lost in the memory. The contents of the buffer can be transferred to the printer or transmitted via the RS-232 port.

The measured data can be stored individually one by one, or it can be automatically stored at a time according to the previously set time period.

RS-232 port: RS-232 port (DTE), 9600 baud, semi-bidirectional, 1 start bit, 8 data bits, 1 stop bit, no parity. More than 20 software instructions for measurement and diagnostics.

Built-in 15 types of conventional fuel can be selected as needed or edited by the customer using ENERACTM software.

You can choose to auto zero. The software automatically performs span calibration for CO, NO, NO2, SO2, combustion gas, and smoke draft.

 

 

Parameter Introduction

Measurement Parameters

Range

Precision

Accuracy

Remarks

Ambient temperature

-18 - 65℃

1℃

2℃

Integrated circuit sensor. The unit is Fahrenheit or Celsius

Flue gas temperature

0-1100℃

1℃

3℃

K type thermocouple. The unit is Fahrenheit or Celsius

Oxygen

0-25%

0.1%

0.2%

Electrochemical sensors. 2 years of service life

Nitric oxide
(NO)

0-2000PPM

1PPM

4% of reading

Electrochemical sensors. 2 years of service life

Nitrogen dioxide
(NO2)

0-1000PPM

1PPM

4% of reading

Electrochemical sensors. 2 years of service life

Carbon monoxide
(CO)

0-2000PPM(The range of options is
:10,000和20,000PPM)

1PPM

4% of reading

Electrochemical sensors. 2 years of service life

Sulfur dioxide
(S02)

0-2000PPM

1PPM

4% of reading

Electrochemical sensors. 2 years of service life

Electrochemical sensors. 2 years of service life

0-5%

0.1%

10% of reading

Catalytic sensor. Unlimited use

Smoke draft

+254 to -1016mm water column

2.54mm水柱

5% of reading or 7.6mm water column

Piezoresistive sensor. Unlimited use

Time/date

The time is in the format of hours, minutes and seconds. The date is in the format of month, day, and year.

         

Calculation Parameters

Range

Precision

Accuracy

Remarks

Combustion efficiency

0-100%

0.1%

1%

Heat loss method

carbon dioxide
(C02)

0-40%

0.1%

5% of reading

 

Excess air

0-1000%

1%

10% of reading

 

Nitrogen oxides
(NOx)

0-3000PPM

1PPM

4% of reading

 

Amount of smoke in pounds per million BTU (CO,NO,NO2,NOX,SO2)

0-99.99Pounds per million
BTU

0.01% pounds/million BTU

5% of reading

 

The amount of smoke in grams/brake horsepower·hours (CO,NO,NO2,NOX,SO2)

0-99.99Gram/brake horsepower

0.01 grams/brake horsepower·hours

10% of reading

 

 

(The unit of the oxygen calibration factor of the flue gas can be adjusted in the range of 0-20% per 1%, or modulated to TRUE if it is PPM) (blue font indicates: recommended configuration; black font indicates: optional configuration) .

 

Product Configuration:

 

1 host (including O2 & CO2), 1 flue gas/ambient temperature unit, 1 combustion rate unit, 1 excess air, 1 cooler, 1 standard probe (9 inches long), 1 software, 4 AA power supply, 1 charger, 1 Chinese and English manual and instrument box.

 

Optional Configuration:

 

 

CO, NO, NOX, NO2, SO2 sensor unit, smoke blackness detection unit, calibration gas, filter element, main/sub filter dryer, 9" sensor extension rod, micro printer, printing paper, PDA handheld computer, etc.